Rising Main Sizing

Design flows, diameter range, velocity, detention, pump cycling and pressure class — WSA 04 Sewage Pumping Station Code, Part 1 Section 10 and Appendix D

1Design flows and the feasible diameter range

Appendix D works from the design flows rather than from a chosen pipe. Enter the flows and the length to the high point and the calculator returns the range of internal diameters that satisfies every WSA 04 constraint; then trial a size against the pumping rate you intend to run. Everything downstream — velocity, detention, starts, head, pressure class — follows from those two choices.

D3.1 · D3.2
Default constraints — D4.1, over-ride only as the water agency authorises

2Trial size

Pick a pipe and a pumping rate. The pumping rate must sit between Qp-min (the greater of the design wet weather flow and the slime-stripping flow) and Qp-max (the maximum velocity limit) — the calculator shows both, and tells you what the trial rate does to starts, detention and velocity.

3Every size, the same flows

The whole catalogue against this station's flows at the trial pumping rate. Sizes outside the feasible diameter range are greyed; the governing limit for each row is named. This is the comparison that decides the size, so the head and pressure columns carry the trial rate through to the pump too. How hard each size is on the pipe itself — cycling, velocity and temperature — is on the Pipe life tab.

Bores are typical manufactured mean internal diameters — confirm against the supplier's table before ordering. WSA 04 uses the internal diameter throughout (Preface).