Sewage Pipe & Pressure Checker

Velocity and pressure across a rising main or station discharge · Colebrook–White to WSA 04 · 0.9 m/s minimum, 3.5 m/s maximum

Concept check — not a design. This answers “is that roughly big enough?” and “roughly what head will it cost?” for a rising main, a pump discharge or any sewage pressure pipe. WSA 04 requires Darcy–Weisbach with Colebrook–White for pressure mains (Cl 10.3.3) — that is the default here — and it sets the velocity limits at 0.9 m/s minimum below DN 300, 1.5 m/s preferred and 3.5 m/s maximum (Cl 10.3.5). For the sizing of the main itself — diameter range, slime stripping, detention time, pump starts and pressure class — use the Rising Main calculator.

Inputs